Vert Biotech Spine Series MT Atlas premium spinal decompression table for non-surgical disc treatment. The future of spinal decompression.

MT ATLAS

The ultimate evolution in non-surgical spinal decompression

If you’ve been treating complex disc cases manually for years, you already know the toll it takes — not just on your patients, but on your own body.

The Spine MT Atlas was designed for that exact moment when you realise working harder isn’t the answer — working smarter is.

This is more than a decompression table. It’s a system that combines multi-rotational decompression, lateral flexion, and targeted mobilisation across the cervical, thoracic, and lumbar regions — giving you the power to treat cases that used to drain your time and your energy.

It’s the next evolution in clinical care — where precision meets scalability.

Every session is automated, trackable, and patient-specific, letting you achieve results you can measure, while freeing yourself from the constant physical grind of manual therapy.

In short — MT Atlas doesn’t just help your patients recover. It helps you reclaim longevity, confidence, and growth.

FEATURES

  • Multi-Rotational Decompression System – Targets every spinal region — cervical, thoracic, lumbar, sacral and pelvic — through true 3-axis control for fully individualised decompression.
  • Five Automated Mobilisation Modes
  • Mob 1: Twisting motion to activate joints.
  • Mob 2: Lateral movement with twisting for multi-plane engagement.
  • Rot: Rotational-only mode (up to 18°) to expand passive ROM.
  • De-Rot: Decompression while in a rotated position for deeper disc release.
  • Mob-Rot: Combined mobilisation + rotation for full spinal mobility.
  • Lateral Flexion Control – Independent cervical and lumbar lateral-flexion modes open one-sided facet or joint injuries to restore symmetry and relieve tension.
  • Cervical Extension Decompression – Advanced treatment modes at -5° and -10° for postural correction and cervical stability.
  • Target Angle Control: Cervical -10°-0–15° | Lumbar 0–25°.
  • Fully Customisable Mobilisation Speed – Adjust intensity to match each patient’s tolerance and stage of recovery.
  • Temperature-Controlled Bedding – Maintains ideal comfort and relaxation throughout treatment.
  • Real-Time Decompression Graph & Timer – Displays live tension feedback and elapsed time to both patient and practitioner.
  • State-of-the-Art Interactive LED Display – Delivers visual feedback and an educational PowerPoint presentation during treatment, increasing understanding and compliance.
  • Patient Progress Tracking
  • Records and compares VAS pain scores across sessions.
  • Prints treatment summaries and progress reports.
  • Three Independent Mobilisation Stops – Enables precise range and motion control with enhanced patient safety.
  • Advanced Control System – Micro-adjusts decompression and rotation in real time for millimetre accuracy.
  • Multiple Pre-Programmed Treatment Protocols – Intelligent programs with full customisation for herniation type, direction, and level.
  • Built-In Patient Mobilisation Test – Establishes a baseline safely before decompression begins.
  • Additional Traction via Gravitational Pull – Enhances natural joint separation and decompression depth.
  • Mobilisation for Spinal Joints and Muscles – Promotes soft-tissue flexibility and joint alignment.
  • Three-Dimensional Disc Decompression Therapy – Integrates Cox flexion-distraction and Cyriax rotation-distraction principles.
  • In-Built Safety Monitoring System – Continuous load sensing with emergency stop and return-to-start controls.
  • Enhanced Ergonomic Design – Optimised for comfort, access, and clinical workflow.
  • Real-Time Feedback and Monitoring – Maintains stable decompression and consistent results every session.


BENEFITS (CLINICAL)

  • Precise, evidence-based decompression with lower practitioner effort.
  • Restores spinal mobility and reduces nerve compression.
  • Opens one-sided joint restrictions through targeted lateral flexion.
  • Enhances posture and deep-muscle relaxation.
  • Tracks patient outcomes for measurable progress and confidence.
  • Enables high-volume, autonomous treatments — freeing practitioner time.


BENEFITS (PRACTITIONER)

Stop trading your body for your business.

  • After 20 years of bending, twisting, and adjusting, you shouldn’t feel more pain than the people you treat. The K-2 lets you deliver powerful results without physically pushing yourself to the limit.

Treat complex disc patients with certainty — not guesswork.

  • Whether it’s lateral herniation, stenosis, or scoliosis, the K-2 automatically calibrates decompression angles for each level and direction, giving you precision that manual therapy simply can’t match.

Increase your clinic’s capacity without hiring more staff.

  • The MT Atlas runs autonomously with real-time safety feedback and live decompression monitoring — meaning more treatments per week and a higher ROI without burning out.

Turn frustration into confidence.

  • No more hoping a tough case responds. The K-2 gives you control, consistency, and measurable progress for every patient.

Enhance patient trust through data and transparency.

  • Real-time force graphs, pain score tracking, and progress reports show patients their improvements session to session — improving retention and compliance.

Stay ahead in a competitive market.

  • While others fight for attention offering the same manual treatments, you’ll be leading with cutting-edge technology — something patients talk about and other clinics want to replicate.

Extend your career, not your hours.

  • This is the associate that never gets tired, sore, or needs time off. One system. Infinite leverage.


CONDITIONS TREATED

  • Cervical and Lumbar Disc Herniation
  • Text Neck
  • Degenerative Disc Disease
  • Spinal Stenosis
  • Scoliosis
  • Facet Joint Syndrome
  • Myofascial Pain Syndrome
  • Sciatica and Radiculopathy


CONTRAINDICATIONS

  • Acute spinal fracture
  • Post Spine Surgery (less than 6 months post)
  • Post-surgical instability or hardware failure
  • Malignancy within treatment area
  • Severe osteoporosis or infection
  • Spinal cord compression requiring surgery
  • Late pregnancy


SPECIFICATIONS

  • Dimensions: 3000 mm (L) × 1100mm (W) × 2274 mm (H)
  • 4 Part Assembly - Minimum 700mm width required for install.
  • Weight: 250kg
  • Power: 220–240 V, 50–60 Hz
  • Maximum Decompression Force: 90 kg (lumbar) / 30 kg (cervical)
  • Treatment Angles:
  • Lumbar: 0°–25° tilt range
  • Cervical: -10° to +15° (flexion/extension)
  • Rotation Range: Up to 18°